Project

General

Profile

Actions

RunPlan20170528

Take straight track data with and without the liquid hydrogen gaseous neon absorber

Data Requested

  • Data with absorber filled with liquid hydrogen gaseous neon
  • Data with absorber empty
  • Data at interstitial momentum points * if time allows *

3-170 MeV/c

Particle Species Pz @ TKU Station 5 Proton Absorber Diffuser setting Q1 Q2 Q3 D1 DS D2 Q4 Q5 Q6 Q7 Q8 Q9 RunControl Tag
MeV/c mm A A A A A A A A A A A A
muons/pions 170 29 no diffuser 54.12 67.56 46.97 160.8 353.33 86.55 144.68 194.03 128.6 124.87 188.89 161.24 3-170+M3-Test1

Repeat with identical beam line settings and absorber empty

3-200 MeV/c

Particle Species Pz @ TKU Station 5 Proton Absorber Diffuser setting Q1 Q2 Q3 D1 DS D2 Q4 Q5 Q6 Q7 Q8 Q9 RunControl Tag
MeV/c mm A A A A A A A A A A A A
muons/pions 200 29 no diffuser 60.74 75.84 52.74 180.7 395.77 94.91 159.44 213.82 141.76 69.99 105.93 90.44 3-200+M3-Test1

Repeat with identical beam line settings and absorber empty

3-240 MeV/c

Particle Species Pz @ TKU Station 5 Proton Absorber Diffuser setting Q1 Q2 Q3 D1 DS D2 Q4 Q5 Q6 Q7 Q8 Q9 RunControl Tag
MeV/c mm A A A A A A A A A A A A
muons/pions 240 29 no diffuser 70.38 87.9 61.14 210.61 459.00 110.82 187.59 251.57 166.86 235.68 356.81 304.90 3-240+M3-Test1

Repeat with identical beam line settings and absorber empty

Task Summary

Task Momentum # Particle Triggers Beamline Tag ColingChannel Tag Similar runs Final Event Tally (k) @ 10am
170GNe S9a 170 1000k at TOF1 3-170+M3-Test1 StepIV-Off
200GNe S9b 200 1000k at TOF1 3-200+M3-Test1 StepIV-Off
240GNe S9c 240 1000k at TOF1 3-240+M3-Test1 StepIV-Off
140GNe S9d 140 1000k at TOF1 3-140+M3-Test2 StepIV-Off

Alignment:

Task Momentum # Particle Triggers Beamline Tag ColingChannel Tag Similar runs Final Event Tally (k) @ 10am
S10a 300 1000k at TOF1 300MeV+pi pa82 StepIV-Off 8030 400
S10b 400 1000k at TOF1 400MeV+pi pa82 StepIV-Off 8041

Empty running:

Task Momentum # Particle Triggers Beamline Tag ColingChannel Tag Similar runs Final Event Tally (k) @ 10am
170Empty S11a 170 1000k at TOF1 3-170+M3-Test1 StepIV-Off
200Empty S11b 200 1000k at TOF1 3-200+M3-Test1 StepIV-Off
240Empty S11c 240 1000k at TOF1 3-240+M3-Test1 StepIV-Off
140Enpty S11d 140 1000k at TOF1 3-140+M3-Test2 StepIV-Off

Interstitial P Points

3-140 MeV/c

Particle Species Pz @ TKU Station 5 Proton Absorber Diffuser setting Q1 Q2 Q3 D1 DS D2 Q4 Q5 Q6 Q7 Q8 Q9 RunControl Tag
MeV/c mm A A A A A A A A A A A A
muons/pions 140 29 no diffuser 47.98 59.88 41.62 142.66 311.97 70.0 131.25 176.01 116.62 110.74 167.46 142.87 3-140+M3-Test2

3-185 MeV/c

Particle Species Pz @ TKU Station 5 Proton Absorber Diffuser setting Q1 Q2 Q3 D1 DS D2 Q4 Q5 Q6 Q7 Q8 Q9 RunControl Tag
MeV/c mm A A A A A A A A A A A A
muons/pions 185 29 no diffuser 57.18 71.39 49.64 169.95 372.41 91.11 152.73 204.83 135.78 133.18 201.50 172.05 3-185+M3-Test1

3-220 MeV/c

Particle Species Pz @ TKU Station 5 Proton Absorber Diffuser setting Q1 Q2 Q3 D1 DS D2 Q4 Q5 Q6 Q7 Q8 Q9 RunControl Tag
MeV/c mm A A A A A A A A A A A A
muons/pions 220 29 no diffuser 63.51 81.56 56.72 194.73 425.76 103.25 174.19 233.60 154.91 154.98 234.55 200.36 3-220+M3-Test1

Task Summary for additional P points

Task Momentum # Particle Triggers Beamline Tag ColingChannel Tag Similar runs Final Event Tally (k) @ 10am
140Hydrogen 140 1000k at TOF1 3-140+M3-Test1 StepIV-Off
180Hydrogen 180 1000k at TOF1 3-180+M3-Test1 StepIV-Off
220Hydrogen 220 1000k at TOF1 3-220+M3-Test1 StepIV-Off
140Empty 140 1000k at TOF1 3-140+M3-Test1 StepIV-Off
180Empty 180 1000k at TOF1 3-180+M3-Test1 StepIV-Off
220Empty 220 1000k at TOF1 3-220+M3-Test1 StepIV-Off

Updated by Overton, Edward almost 6 years ago · 19 revisions