Actions
RunPlan20150911¶
September | 11th and/or 12th | 11th and/or 12th |
estimated time | 8:00-16:00 | 16:00-00:00 |
MOM | V. Blackmore | V. Blackmore |
Expert Supervisor | C. Rogers, M. Bogomilov, E. Overton, D. Rajaram | C. Rogers, M. Bogomilov, E. Overton, D. Rajaram |
Lead shifter | Ao Liu | Antonio de Bari |
Shifter 2 | Chris Booth | Maurizio Bonesini |
BLOC | C. Heidt | C. Heidt |
SOC | ||
Aim | Take data with SSU on full current | |
Beam? | Yes | Yes |
Beamline Configurations¶
We expect to be running with 2V beamloss and beam bump active.
Data plan¶
Assuming beam starts at 8am and ends at 10pm (14 hours)
- Pion reference run: settings from Run Control (30 min)
- Tracker timing studies (see below): settings from Run Control (2 hours)
- Pion reference run: settings from Run Control (30 min)
- (3pi, 200) beam line settings from Run Control (2 hours)
- Pion reference run: settings from Run Control (30 min)
- (3pi, 200) beam line settings from Run Control (2 hours)
- Pion reference run: settings from Run Control (30 min)
- (3pi, 200) beam line settings from Run Control (2 hours)
- Pion reference run: settings from Run Control (30 min)
- (3pi, 200) beam line settings from Run Control (2 hours)
- Pion reference run: settings from Run Control (30 min)
- (6pi, 200) beam line settings from Run Control (1 hour)
Tracker timing studies (2 hours)¶
Use the following standard pion reference beam (and check this is the std. reference beam):
Particle Species | p at Tgt | p@D1 | p@D2 | Proton Absorber | Q1 | Q2 | Q3 | D1 | DS | D2 | Q4 | Q5 | Q6 | Q7 | Q8 | Q9 | Similar Run(s) |
mm | A | A | A | A | A | A | A | A | A | A | A | A | A | A | A | A | DAQ run # |
Pion Reference | ? | ? | ? | 29 | 57.8 | 105.7 | 64.5 | 202.8 | --- | 176.9 | 237.1 | 157.2 | 157.6 | 238.5 | 125.70 | 203.7 | 7257 |
I would like the following runs:
Target is 25K Triggers in TOF1 per run
Run Type | Timing FileName | Efficiency | Alive Window | Alive Window | Est. | Run # |
(Trig/Request) | Delay (ns) | Width (ns) | Spills | |||
Nominal | Nominal.cfg | 0.8 | 130 | 110 (116.4 meas.) | 1400 (20min) | 7285 |
Section1 | Timing_section1.cfg | <0.2 | 130 | 30 (35 meas.) | 5600 (2hr) | ?? |
Section2 | Timing_section2.cfg | >0.2 | 130 | 30 (30 meas.) | 5600 (2hr) | ?? |
Section3 | Timing_section3.cfg | >0.2 | 130 | 30 (35 meas.) | 5600 (2hr) | ?? |
Section4 | Timing_section4.cfg | <0.2 | 130 | 30 (35 meas.) | 5600 (2hr) | ?? |
Phone details for 9am daily meeting¶
Phone access : ReadyTalk number
US 866-740-1260
UK 0800-496-0576
Swiss 0800-70-53-51
Italy 800182592
Access Code: 2155402