Project

General

Profile

OtherSafetyAlarms » History » Version 14

Boyd, Steven, 26 August 2015 13:58

1 1 Boyd, Steven
h1. Emergency Procedures and responses to alarms during MICE Step IV
2 2 Boyd, Steven
3 3 Boyd, Steven
The MICE experiment is being hosted by STFC at its ISIS facility on behalf of the International MICE Collaboration. 
4 1 Boyd, Steven
5 3 Boyd, Steven
Emergency procedures at the top-level are as per STFC’s safety policy and can be found here:
6
7 2 Boyd, Steven
http://www.stfc.ac.uk/SHE/Emergencies/21035.aspx
8
9 1 Boyd, Steven
All STFC employees and all MICE visiting staff without exception are strictly required to attend the basic STFC safety induction course, where these emergency procedures are described. The course has to be re-taken every two years.
10 3 Boyd, Steven
11 1 Boyd, Steven
In addition to the above, there are four specialised situations in MICE, which require the following responses:
12 3 Boyd, Steven
13
h2. 1. In R5.2 with blue lighting illuminated
14
15
+Press nearest Beam-Off Button (BOB) and leave the building immediately via nearest crash-out gate+
16
17 4 Boyd, Steven
h2. 2. Power Cut to the Hall
18
19
+Notify the MOM immediatey+
20
21
If power is +not restored+ within one hour
22
23
If an ODH alarm *is not* indicated, any PPS search must be cancelled and the Auxiliary Door unlocked and opened.
24 5 Boyd, Steven
If an ODH alarm *is* indicated, 
25
26 7 Boyd, Steven
# the exterior doors to the MICE Hall must be padlocked (in accordance with Section 4.2.7.3 of
27 5 Boyd, Steven
the MICE PPS User Guide "here":http://micewww.pp.rl.ac.uk/documents/41)
28 7 Boyd, Steven
# the PPS search is cancelled 
29
# the Fortress key must be removed from the Auxiliary Door keyswitch
30 4 Boyd, Steven
31 9 Nebrensky, Henry
h2. 3. Neutron monitor alarm in R5.2 sounds (attachment:NeutronMonitorAlarm.wav) and beacon illuminated:
32 3 Boyd, Steven
33
+Leave the building immediately+
34
35 13 Boyd, Steven
+Contact the MOM : +44 (0)7789 272 992+
36
37 14 Boyd, Steven
+Do not re-enter the Hall without permission from the MOM+
38
39 10 Bayes, Ryan
h2. 4. ODH (Oxygen Deficiency Hazard) alarm in R5.2 sounds (attachment:Permanent_ODH_Monitor.wav) and beacons illuminated:
40 3 Boyd, Steven
41 12 Boyd, Steven
+If inside the hall, leave immediately+
42 1 Boyd, Steven
43 13 Boyd, Steven
+Contact the MOM : +44 (0)7789 272 992+
44 12 Boyd, Steven
45
+Do not re-enter the Hall without permission from the MOM+
46
47 3 Boyd, Steven
48 8 Boyd, Steven
h2. 5. Hydrogen alarm outside MLCR (MICE Local Control Room) sounds and beacon illuminated:
49 3 Boyd, Steven
50
(Note that at all times during operation with liquid hydrogen, a member of the hydrogen expert team will be present)
51
52
If a consensus is reached between MICE LH2 experts and the ISIS MCR that the risk of an unforeseen and catastrophic hydrogen incident is heightened and developing, evacuation must be considered. In this scenario, *+the nearest fire alarm should be activated*+. The alarm should only be silenced once a Hydrogen Expert has determined that the risk level has dropped.
53
54
+It must be stressed that the decision to sound the fire alarm must include input from the ISIS MCR.+
55
56
Some ISIS MCR personnel may remain in the MCR as it is an essential site communications hub. This will be at their own discretion.
57
58
The RAL site Alarm Investigation Team (AIT) should be contacted and liaise with the MICE team to clarify the situation.
59
60
RAL Security should be asked to inform the Site Emergency Controller, by the MOM.
61
62
The above alarms and locations are pointed out to each employee & and visitor at the induction training and escape routes and
63
exits are described.
64
65
+In any of the above emergency situation, the MOM (MICE Operations Manager) has authority and MICE staff should defer to the MOM+