Actions
How to move D1 and D2 - Draft¶
D2¶
- Disconnect POMPOM/polarity sensor
- Check power and earth cables on D2
- Remove water hose bracket above D2, arrange temporary support during magnet movement.
- Remove chock
- Start moving - watch earth and interlock cables
- Stop moving!
- Replace chock
Replacement¶
I think it will be opposite of above, i.e.:
- Remove chock
- Start moving - watch earth and interlock cables
- Stop moving!
- Replace chock
- Reattach water hose bracket above D2
- Check power and earth cables on D2
- Reconnect POMPOM/polarity sensor
- Check POMPOM sensor signal
- Power magnet to 50 A, and confirm all connection and interlocks OK and that POMPOM polarity reading is correct
D1¶
- Disconnect POMPOM/polarity sensor
- Disconnect power cables D1
- Disconnect water supply on D1
- Remove chock
- Start moving - watch earth and interlock cables
- Stop moving!
- Replace chock