Project

General

Profile

2016-03-21 Physics and Processing Requirements for IPAC » History » Version 6

Rogers, Chris, 30 March 2017 11:07

1 1 Rogers, Chris
h1. 2016-03-21 Physics and Processing Requirements for IPAC
2
3
Thinking about the "measurement of emittance evolution" paper
4
5 6 Rogers, Chris
| *Measurement Uncertainty*   | *Mitigation/Estimation Strategy* |
6 1 Rogers, Chris
| Detector Resolution | MC of "best guess" lattice |
7
|                     | Track extrapolation |
8
| Efficiency          | MC of "best guess" lattice |
9
|                     | Track extrapolation |
10
| Tracker field magnitude   | Hall probes give magnitude of uncertainty|
11
|                           | Dead reckoning with COMSOL gives magnitude of uncertainty |
12
|                           | MC with wrong current field gives magnitude of measurement error |
13
| Detector and SS alignment | Track extrapolation/residuals gives magnitude of uncertainty |
14
|                           | Survey probably doesn't help for SS and tracker |
15
|                           | MC with misalignment gives magnitude of measurement error |
16 4 Rogers, Chris
| Selection Biases          | Move selections around; examine change in measurement |
17 5 Rogers, Chris
| *Model Uncertainty*    | *Mitigation/Estimation Strategy* |
18 1 Rogers, Chris
| Magnet Alignments | Track extrapolation/residuals gives magnitude of uncertainty |
19
|                   | Survey may help for FC |
20
|                   | MC with wrong current field/misalignments gives magnitude of MC uncertainty |
21
| Material Budget   | LiH MICE note tells us material budget and uncertainty | 
22
|                   | Thumb in air tells us He and window budget and uncertainty | 
23
|                   | MC with wrong material budget gives magnitude of MC uncertainty |
24
25
Require:
26
27
* "Best guess" lattice and MC thereof
28
* Final version of MAUS Tracker recon/etc
29 3 Long, Kenneth
* For each parameter, we might need, say, 4 MC jobs (small and large negative and positive offsets). Parameters are:
30 1 Rogers, Chris
** Current of each of 10 coils
31
** Alignment of each of 3 modules - assume coil-by-coil alignment is okay; 3 position offsets and 2 tilts
32
** Alignment of each of TKU and TKD - 3 position offsets and 2 tilts
33
** LiH thickness
34
** 2 Window thicknesses
35
* MC should be supported with appropriate back-of-envelope calculation. Fall back to back-of-the-envelope where possible...
36
37
Would like 100k muons inside analysis cuts for each MC job.
38
39
Other things I ignore:
40
* Apertures/uncertainty
41
* Anything else?