Project

General

Profile

2016-03-21 Physics and Processing Requirements for IPAC » History » Version 3

Long, Kenneth, 21 March 2017 14:35

1 1 Rogers, Chris
h1. 2016-03-21 Physics and Processing Requirements for IPAC
2
3
Thinking about the "measurement of emittance evolution" paper
4
5
| *Measurement Bias*   | *Mitigation/Estimation Strategy* |
6
| Detector Resolution | MC of "best guess" lattice |
7
|                     | Track extrapolation |
8
| Efficiency          | MC of "best guess" lattice |
9
|                     | Track extrapolation |
10
| Tracker field magnitude   | Hall probes give magnitude of uncertainty|
11
|                           | Dead reckoning with COMSOL gives magnitude of uncertainty |
12
|                           | MC with wrong current field gives magnitude of measurement error |
13
| Detector and SS alignment | Track extrapolation/residuals gives magnitude of uncertainty |
14
|                           | Survey probably doesn't help for SS and tracker |
15
|                           | MC with misalignment gives magnitude of measurement error |
16
| *Model Bias*    | *Mitigation/Estimation Strategy* |
17
| Magnet Alignments | Track extrapolation/residuals gives magnitude of uncertainty |
18
|                   | Survey may help for FC |
19
|                   | MC with wrong current field/misalignments gives magnitude of MC uncertainty |
20
| Material Budget   | LiH MICE note tells us material budget and uncertainty | 
21
|                   | Thumb in air tells us He and window budget and uncertainty | 
22
|                   | MC with wrong material budget gives magnitude of MC uncertainty |
23
24
Require:
25
26
* "Best guess" lattice and MC thereof
27
* Final version of MAUS Tracker recon/etc
28 3 Long, Kenneth
* For each parameter, we might need, say, 4 MC jobs (small and large negative and positive offsets). Parameters are:
29 1 Rogers, Chris
** Current of each of 10 coils
30
** Alignment of each of 3 modules - assume coil-by-coil alignment is okay; 3 position offsets and 2 tilts
31
** Alignment of each of TKU and TKD - 3 position offsets and 2 tilts
32
** LiH thickness
33
** 2 Window thicknesses
34
* MC should be supported with appropriate back-of-envelope calculation. Fall back to back-of-the-envelope where possible...
35
36
Would like 100k muons inside analysis cuts for each MC job.
37
38
Other things I ignore:
39
* Apertures/uncertainty
40
* Anything else?