So we need to decide a set of beam settings for the run next week. It looks like the software won't quite be ready yet, so probably we need to bank some data and get analysis ready for, say, the Collaboration Meeting (humm, maybe we could ask for a slot in analysis session? In which case probably needs a presentation at an analysis meeting before the CM...).

So I think something like:
  • some pion beams, which are impure but have a narrow momentum spread
  • some muon beams, which are pure but have a wider momentum spread.
  • a few different momentum settings to let us test reconstruction over a reasonable range of conditions
  • some measurements with Q7-9 off, to test reconstruction with only material effects (straight tracks)
  • some measurements with Q7-9 set to "some value" so that we can mix and match input beams with the same reconstruction
  • some measurements with Q7-9 scaled with momentum
  • it would be nice to fill the aperture upstream so we can see effect of high amplitude particles (which are probably going through non-linear region of the magnet). I'm not really sure how to do that...
We have one shift scheduled in the end, which is I guess enough time to get say 15 beam settings with 10k triggers on each setting
  • 50 triggers per 3 seconds = 1000 triggers per minute
  • 10k particles in 10 minutes of beam plus 5 minutes of set up
  • 16 settings * 15 minutes = 4 hours of running
  • Add 2 hours of faff factor + 2 hours of start-up and shut-down

We might be able to fit in a little bit more time than that. So...

Beam Beam Momentum (MeV/c) Current (A)
Species Q1-6 Q7-9 P @ Tgt P @ D1 P @ D2 Prot Absorber Q1 Q2 Q3 D1 Sol D2 Q4 Q5 Q6 Q7 Q8 Q9 Complete Run No.
pion 140 off 202.4 197.89 194.57 15 50.14 62.58 43.50 149.00 326.14 77.66 128.79 172.71 114.36 0.0 0.0 0.0 Yes 4099
pion 140 200 202.4 197.89 194.57 15 50.14 62.58 43.50 149.00 326.14 77.66 128.79 172.71 114.36 141.64 214.27 182.92 Yes 4100
pion 140 140 202.4 197.89 194.57 15 50.14 62.58 43.50 149.00 326.14 77.66 128.79 172.71 114.36 106.03 160.21 136.50 Yes 4101
muon 140 off 327.6 324.11 188.86 29 81.92 102.33 71.18 248.44 534.62 75.47 125.19 167.89 111.22 0.0 0.0 0.0 Yes 4087
muon 140 200 327.6 324.11 188.86 29 81.92 102.33 71.18 248.44 534.62 75.47 125.19 167.89 111.22 138.67 209.82 179.18 Yes 4088
muon 140 140 327.6 324.11 188.86 29 81.92 102.33 71.18 248.44 534.62 75.47 125.19 167.89 111.22 104.22 157.56 134.37 Yes 4089
pion 200 off 249.8 245.88 243.05 15 62.21 77.68 54.02 185.19 405.44 96.12 161.43 216.49 143.50 0.0 0.0 0.0 Yes 4102
pion 200 200 249.8 245.88 243.05 15 62.21 77.68 54.02 185.19 405.44 96.12 161.43 216.49 143.50 141.64 214.27 182.92 Yes 4103
muon 200 off 408.60 405.27 238.00 83 102.38 127.91 89.00 323.15 668.63 94.15 158.1 212.02 140.57 0.0 0.0 0.0 Yes 4094
muon 200 200 408.60 405.27 238.00 83 102.38 127.91 89.00 323.15 668.63 94.15 158.1 212.02 140.57 138.67 209.82 179.18 Yes 4095
pion 240 off 285.4 281.74 279.10 29 71.24 88.98 61.89 213.36 464.66 109.77 185.64 248.95 165.09 0.0 0.0 0.0 Yes 4090
pion 240 200 285.4 281.74 279.10 29 71.24 88.98 61.89 213.36 464.66 109.77 185.64 248.95 165.09 141.64 214.27 182.92 Yes 4091
pion 240 240 285.4 281.74 279.10 29 71.24 88.98 61.89 213.36 464.66 109.77 185.64 248.95 165.09 166.66 252.22 215.45 Yes 4092
muon 240 off 471.60 468.33 275.88 83 118.28 147.79 102.84 390.20 773.00 108.50 213.88 313.14 198.35 0.0 0.0 0.0 Yes 4096
muon 240 200 471.60 468.33 275.88 83 118.28 147.79 102.84 390.20 773.00 108.50 213.88 313.14 198.35 138.67 209.82 179.18 Yes 4097
muon 240 240 471.60 468.33 275.88 83 118.28 147.79 102.84 390.20 773.00 108.50 213.88 313.14 198.35 152.72 264.17 224.46 Yes 4098

Per our discussion with Linda, proton absorber should be set to 15 mm for 140 and 200 MeV/c case, and to 29 mm for 240 MeV/c case, at least for pion beams. Not sure about muons.
Linda and Pierrick went through and tried to determine in a sensible manner what proton absorber setting to use both for useful proton absorbing and ease of Operations. Changes included in table.

Magnet currents are taken from http://mice.iit.edu/mico/mom/RunConditionSummary.xls, crosschecked with http://mice.iit.edu/bl/Documentation/PION_MUON-BL-MAGIC-TABLE-v170809.xls