h1. 2019-03-18 amp-evolv
2
3
17:00 GMT Monday 18th March
4
5
http://mice.iit.edu/phonebridge.html
6
7
h2. Actions
8
9
intro (KL)
10
-0th paragraph add section headings
11
-1st paragraph needs revision; check historical details
12
-3rd paragraph need caveat on e+e-
13
4th paragraph need frictional cooling
14
15
observables (CR)
16
-introduce cooling formula; but phrased ito amplitude (FD)- -_CR to integrate with paper (CR)_-
17
-remove sentence regarding 9% centile just before eq 1-
18
-Add a sentence regarding "human readable" what is kNN algorithm- -_FD to check CR's understanding (FD)_-
19
-Joining sentence between "observables" and "MICE"-
20
21
MICE
22
(CR) -contact Jason Tarrant and photo repro regarding image- _for now keep working on it amongst ourselves_
23
(FD) -upload schematic latex to overleaf-
24
(FD) -Add labels to schematic; make lH2 not LiH absorber; general "look and feel" stuff-
25
(CR) -remove phase space figure to MICE note; consider 2d amplitude plot instead a la Francois thesis figure 6.25-
26
27
28
Results
29
(CR) francois asked by email - why is mc_reco sample size not same as reco sample size (they are supposed to be same sample _it is impurity at high radius (tracks in MC fiducial but not data fiducial); is impurity properly handled by correction mechanism? Need to check; relies on migration matrix non-unitary_
30
(CR) -investigate the 17.5 mm bin issue esp at 10-140- _could check rebinning but low priority for now_
31
(CR) -investigate the scraping aperture _looks like it is MC offset_-; add a vertical line corresponding to the scraping aperture; comment in text
32
(FD) fractional emittance is better than most significant bin as a table
33
(FD) -need to do the efficiency correction on fractional emittance-
34
(FD) -need to do the efficiency correction on density-
35
(CR) -Check apertures in lH2 vs None absorber; KL claims window aperture should be mostly not there in "None"-
36
(CR/FD) *DONE* Check systematic for density plot in TKU 10 mm; why is SSU CC giving such large uncertainty?
37
38
h2. Notes from CM53
39
40
41
Try Nature before Nature physics
42
43
Fig. 1 - schematic
44
(CR) -Preferably plot B_{z}, or introduce an arbitrary factor of -1 after the absorber, or label as |B|-
45
(CR) -Note that the sigma(x) plot comes from linear beam optics calculation-
46
47
Fig. 2 - phase space 2d plots
48
(CR) Interesting that there is a cliff in the x-py and y-px plots. Is this diffuser aperture (or some other aperture)
49
(CR) If show Phase space plots, put one beam ellipse on
50
51
Fig. 3 - amplitude pdf
52
(CR) Add the amplitude pdf plot without corrections to the supplementary information
53
(CR) -Plot amplitude pdf as a histogram or without horizontal errors-
54
(CR) Afterwards, JHC pointed out that log(n) vs sqrt(A) is linear for Gaussian beam. It might just confuse people to plot it.
55
(CR) Vertical axis label is wrong. Normalisation needs to be explained.
56
57
Fig. 4 - pdf ratio
58
(CR) -Make MC less visible in pdf ratio plot - it tends to dominate-
59
(CR) Increase the MC stats (implies going to production MC, it is time)
60
61
Fig. 5 - cdf ratio
62
(CR) -The number of significant figures in the table is too great. Need to understand the difference between the errors for different data-
63
(CR) -John and KL asked for raw pdf numbers-
64
(CR) -Discussion of which bin to choose and how to quantify the level at which we observe cooling-
65
* Soler suggested CLS method
66
* -Others suggested looking at significance of first bin rather than most significant bin-
67
68
(CR) -Move the points to the bin edge, not bin centre; look and feel issues-
69
(CR) Check systematic error correlations are handled correctly
70
71
(CR) -General - check the systematic error is reasonable; e.g. do we need to include big error for SSU and for SSD; check we only use -ve error in SSU-
72
(CR) General - move to production
73
74
h2. Other jobs
75
76
(CR) *DONE* Check - why is the systematic error so much higher on density plot than e.g. amplitude pdf plot?
77
(CR) -Add labels to schematic-
78
(CR) Fix or explain kink in 10-140 plot amplitdue pdf
79
(CR) Write methods section
80
(CR) Update MICE Note
81
(FD) Add comment noting the beam used for the Poincare plot
82
(FD) Add date to the schematic