Project

General

Profile

2017-12-05-physics-shifter » History » Version 14

Rogers, Chris, 08 December 2017 17:41

1 1 Rogers, Chris
h1. 2017-12-05-physics-shifter
2
3
*Start Date:* 2017-12-05
4
*End Date:* 
5
*Start Run:* 10432
6
*End Run:* 
7
*Physics shifter*: Chris Rogers
8
9
h2. Summary
10
11
The aim was to get the empty data for corresponding LiH full settings:
12
13 14 Rogers, Chris
* 5th December - recover magnets following a quench
14 2 Rogers, Chris
* 6th December - 2016-05.1 setting (flip mode, 140 MeV/c)
15
* 7th December - 2017-02-7 setting (flip mode, 140 MeV/c)
16 13 Rogers, Chris
* 8th December - 2017-02-8 setting (flip mode, 170 MeV/c); run abandoned due to heating in SSD coil pack
17 10 Rogers, Chris
* 9th December+ - absorber changeover
18 1 Rogers, Chris
19
h3. Elog, CDB
20
21
22 12 Rogers, Chris
CDB okay.
23
24 1 Rogers, Chris
h3. Online reco
25 12 Rogers, Chris
26
Online reco okay.
27 1 Rogers, Chris
28
29
h2. Analysis
30
31
32
h3. 5th December
33 2 Rogers, Chris
34 3 Rogers, Chris
No data
35 2 Rogers, Chris
36
h3. 6th December
37 4 Rogers, Chris
38
Checked:
39 7 Rogers, Chris
* TOF1 dt is around 50 ps (depending on the run setting), still not great; TOF0 and TOF2 slab conversion to space point efficiency ~ 97-98 %
40 4 Rogers, Chris
* TKU, TKD has no obvious dead area
41
* Amplitude change looks okay. Notice more scraping than with M2D data sets.
42
* I spend some time staring at the chi2 plots in TKD. TKD has a longer tail, but I think it is not significant. Comparing e.g. chi2/ndf = 4, with the peak chi2, the ratio is < 10^-3 for both TKU and TKD. But TKD has a longish tail beyond - all at < 10^-3 level, so did not dig further. I also note TKD has fewer ndf, potentially indicating less successful track finding from PR; again, something to dig into (but data is probably okay).
43 8 Rogers, Chris
** The p-value plot shows p-value around 0 for events that pass cuts. Why is this? Bug in my script?
44 1 Rogers, Chris
* I noted onrec shows lots of electrons in EMR for the diff8 setting. Why is that? This setting has slightly lower pz, maybe lots of stopping muons in KL?
45 7 Rogers, Chris
46
h3. 7th December
47
48 11 Rogers, Chris
Similar comments to 7th Dec. The amplitude upstream vs downstream looks better, because M2D is on!