1 1 Rogers, Chris
h1. 2015 01 Optics Settings
2 2 Rogers, Chris
3
Going through table in 2015/01 v5 run plan...
4
5
h2. TOF Calibration
6
7
This is just a cut and paste from [[operations:RunPlan20150425]]
8
9 16 Rogers, Chris
| Particle Species| p at Tgt | p@D1 | p@D2 | Proton Absorber | Q1  | Q2  | Q3    | D1    | DS    | D2   | Q4     | Q5    | Q6    | Q7   | Q8     | Q9   | SSU E2 | SSU CC | SSU E1 | SSU M2 | SSU M1 | FC     | SSD M1 | SSD M2 | SSD E1 | SSD CC | SSD E2 |
10
|                 | MeV/c    | MeV/c| MeV/c| mm              | A   | A   | A     | A     | A     | A    | A      | A     | A     | A    |A       | A    | A      | A      | A      | A      | A      | A      | A      | A      | A      | A      | A      |
11
| Positron        | 300.0    | 259.7|249.58| 29              |66.29|82.54| 57.23 | 195.91| 426.03| 98.59| 163.16 |218.79 | 144.14| 83.40| 125.70 | 80.06| 0.     | 0.     | 0.     | 0.     | 0.     | 0.     | 0.     | 0.     | 0.     | 0.     | 0.     |
12 1 Rogers, Chris
13
h2. Tracker Hardware commissioning
14 3 Rogers, Chris
15
Upstream tracker; maximal fluence setting:- aim is to get as many particles as possible through the tracker centre, choose muons because they don't decay. No diffuser, low emittance beamline
16
17
Upstream tracker; maximal illumination setting:- aim is to illuminate the upstream tracker reasonably evenly, choose muons because they don't readily decay. High emittance beamline
18
19
Downstream tracker; maximal fluence setting:- we will illuminate the entire downstream tracker no matter what, so here we want to just get the best rate through that we possibly can
20 4 Rogers, Chris
21
h2. Tracker Validation
22
23 5 Rogers, Chris
Downstream tracker; maximal fluence setting:- aim is to illuminate both trackers with as many muons as possible
24 6 Rogers, Chris
25
h2. Beamline Pre-Commissioning
26
27
To be defined.
28
29 7 Rogers, Chris
h2. Tracker External Alignment/External Alignment other detectors
30
31
Downstream tracker; maximal fluence setting:- aim is to illuminate both trackers with as many muons as possible. Take a setting at 140, 200, 240 MeV/c to try to fight residual fields systematic.
32 8 Rogers, Chris
33 9 Rogers, Chris
h2. Validation of track matching
34
35
Muon beam, 3 momenta, scan Q789 for TOF0-1 matching?
36
37
h2. Validation of PID
38
39
Pion beam, different momenta
40
Electron beam?
41
42 8 Rogers, Chris
h2. Beam-Based Alignment
43
44
Run with SSU, three momenta, 10k muons, fiddle with currents to get most fluence
45
Run with SSD, three momenta, 10k muons, fiddle with currents to get most fluence
46
Run with AFC, three momenta, 10k muons, fiddle with currents to get most fluence
47
Run with combined, 10k muons, in baseline optics setting, fiddle with currents to get most fluence
48 10 Rogers, Chris
49 22 Rogers, Chris
| Particle Species| Proton Absorber | Q1  | Q2  | Q3    | D1    | DS    | D2   | Q4     | Q5    | Q6    | Q7   | Q8     | Q9   | Diffuser | SSU E2 | SSU CC | SSU E1 | SSU M2 | SSU M1 | FC     | SSD M1 | SSD M2 | SSD E1 | SSD CC | SSD E2 |
50
|                 | mm              | A   | A   | A     | A     | A     | A    | A      | A     | A     | A    |A       | A    | [Mask]   |A      | A      | A      | A      | A      | A      | A      | A      | A      | A      | A      |
51
| Muon, 140 MeV/c | 29              |66.29|82.54| 57.23 | 195.91| 426.03| 98.59| 163.16 |218.79 | 144.14| 83.40| 125.70 | 80.06| 0000     | 253.00 | 274.00 | 234.00 | 231.75 | 248.39 | 107.8  | 248.39 | 231.75 | 234.00 | 274.00 | 253.00 |
52
| Muon, 200 MeV/c | 29              |66.29|82.54| 57.23 | 195.91| 426.03| 98.59| 163.16 |218.79 | 144.14| 83.40| 125.70 | 80.06| 0000     | 253.00 | 274.00 | 234.00 | 231.75 | 248.39 | 107.8  | 248.39 | 231.75 | 234.00 | 274.00 | 253.00 |
53
| Muon, 240 MeV/c | 29              |66.29|82.54| 57.23 | 195.91| 426.03| 98.59| 163.16 |218.79 | 144.14| 83.40| 125.70 | 80.06| 0000     | 253.00 | 274.00 | 234.00 | 231.75 | 248.39 | 107.8  | 248.39 | 231.75 | 234.00 | 274.00 | 253.00 |
54 11 Rogers, Chris
55
56 10 Rogers, Chris
h2. Beamline Commissioning
57
58
M1 Matrix elements?
59
60
h2. Cooling channel optics validation
61
62
Few momentum settings, few beta function settings, 100k muons?