energy deposition in SciFi is too small

Added by Santos, Edward over 11 years ago. Updated about 11 years ago.

Status:
Rejected
Priority:
Normal
Category:
Simulation
Target version:
Start date:
22 November 2011
Due date:
% Done:

0%

Estimated time:
Workflow:
New Issue

Description

It's been a while since I looked at simulation. Now, I'm having problems running tracker reconstruction with the recent updates in the simulation code. The issue comes down to this: energy depositions in the fibres are too small. They are either 0 or something of the order 10^(-10) keV. Typical values like the ones we used to have before (~ 0.04 keV) are very(!) rare.

The energy deposition in a fibre is retrieved using the member function GetTotalEnergyDeposit() of the class G4Step.

This whole problem is not due to secondaries, I'm running an almost pure muon beam with large threshold for delta ray production. Datacard input and simulation output are attached.

Help? Ideas?


Files

datacard (4.89 KB) datacard input datacard Santos, Edward, 22 November 2011 15:19
simulation.out (271 KB) simulation.out output of the simulation Santos, Edward, 22 November 2011 15:19
energy_deposited.png (9.04 KB) energy_deposited.png Rogers, Chris, 16 December 2011 10:58
santos_run.tgz (68 KB) santos_run.tgz Rogers, Chris, 16 December 2011 10:58