Project

General

Profile

Support #711

Turning off magnetic fields?

Added by Tunnell, Christopher about 12 years ago. Updated about 12 years ago.

Status:
Closed
Priority:
Normal
Assignee:
Tunnell, Christopher
Category:
Fields
Target version:
Start date:
22 September 2011
Due date:
% Done:

100%

Estimated time:
Workflow:

Description

From Anastatia Belozertseva:

Hello,

I was just wondering how to go about controlling the magnetic field in MAUS
switching it off completely. I can't seem to find the switch in the configuration
files. 

Thanks,
Anastasia
#1

Updated by Tunnell, Christopher about 12 years ago

First, the default geometry that's used is specific in ConfigurationDefaults (click here).

That should say Stage6.dat (view the file here).

Which magnets are you wanting to turn off?

If you look here you can see where in Stage6.dat another MICE module is being called that stores the fields.

Looking in the CoilCurrent file that's referenced (click here) you should be able to sent the current density to zero.

PropertyDouble CurrentDensity    0.

For whatever magnets you want off.

You should check what I say (or maybe somebody else who does magnet stuff can comment). Most people turn off material and keep fields; not vice versa.

#2

Updated by Tunnell, Christopher about 12 years ago

  • Status changed from Open to Closed
  • % Done changed from 0 to 100
#3

Updated by Rogers, Chris about 12 years ago

That is correct!