Description

I have been running the tracker real data digitization, and added some cerr statements for when a DAQ hit is found, but matching mapping entry is available. There seem to be a good number for each trigger. Some example output from run 07002 using MAUS 0.9.6:

WARNING: UId 496 not present! chan_ro: 112, bank: 3, board: 0
WARNING: UId 504 not present! chan_ro: 120, bank: 3, board: 0
WARNING: UId 517 not present! chan_ro: 5, bank: 0, board: 1
WARNING: UId 994 not present! chan_ro: 98, bank: 3, board: 1
WARNING: UId 974 not present! chan_ro: 78, bank: 3, board: 1

etc etc.

Is this expected, or does it indicate a problem?

#1

Updated by Dobbs, Adam about 8 years ago

  • Status changed from Open to Closed
  • % Done changed from 0 to 100

Solved, all is well, cause is unused electronics readout channels.