Project

General

Profile

MICE File List » abs_vienna13VP.txt

EMR Abstract Vienna - Palladino, Vittorio, 29 October 2012 20:44

 
1
The MICE beamline PID instrumentation for a precise emittance measurement.
2

    
3
The International Muon Ionization Cooling Experiment (MICE) will carry out
4
a systematic investigation of ionization cooling of a muon beam, for the
5
future Neutrino Factory and the Muon Collider. As the emittance measurement
6
will be done on a particle-by-particle basis, a sophisticated beam 
7
instrumentation is needed to measure both particle coordinates and timing 
8
vs RF in a harsh environment due to high particle rates, fringe magnetic 
9
fields and RF backgrounds. A PID system, based on three x/y time-of-flight 
10
stations (with resolutions around 50 ps), two 
11

    
12
special index of refraction 
13

    
14
Aerogel Cerenkov counters and a 
15

    
16
high resolution 
17

    
18
KLOE-like calorimeter (KL) 
19

    
20
has been constructed and has 
21

    
22
achieved  
23

    
24
the commissioning of the MICE muon beamline.
25
 
26
PID detector performances will be shown and their use for a preliminary
27
estimate of the beamline emittance and the MICE muon beam pion contamination
28
will be illustrated.
29

    