Project

General

Profile

Publications and Figures » History » Version 37

Rogers, Chris, 27 January 2015 12:48

1 37 Rogers, Chris
Publications and figures are available for the following steps:
2 37 Rogers, Chris
3 37 Rogers, Chris
*[[Publications_and_Figures_Step_I|Step 1]]*
4 1 Long, Kenneth
5 10 Blackmore, Victoria
{{toc}}
6 10 Blackmore, Victoria
7 1 Long, Kenneth
h1. Demonstration of ionization cooling
8 1 Long, Kenneth
9 30 Blackmore, Victoria
 
10 30 Blackmore, Victoria
11 11 Blackmore, Victoria
h2. Demonstration of ionization cooling paper titles
12 1 Long, Kenneth
13 1 Long, Kenneth
Documentation & figures
14 30 Blackmore, Victoria
 
15 30 Blackmore, Victoria
 
16 30 Blackmore, Victoria
 
17 25 Blackmore, Victoria
18 25 Blackmore, Victoria
19 1 Long, Kenneth
20 1 Long, Kenneth
h1. Step IV: Measurement of the factors that affect the performance of an ionization cooling channel
21 25 Blackmore, Victoria
22 30 Blackmore, Victoria
 
23 30 Blackmore, Victoria
24 1 Long, Kenneth
h2. Step IV paper titles
25 1 Long, Kenneth
26 1 Long, Kenneth
Documentation & figures
27 30 Blackmore, Victoria
 
28 30 Blackmore, Victoria
 
29 30 Blackmore, Victoria
 
30 25 Blackmore, Victoria
31 25 Blackmore, Victoria
32 1 Long, Kenneth
33 25 Blackmore, Victoria
34 1 Long, Kenneth
h1. Step I: Characterisation of the MICE Muon Beam
35 30 Blackmore, Victoria
 
36 10 Blackmore, Victoria
37 10 Blackmore, Victoria
h2. Characterisation of the muon beams for the Muon Ionization Cooling Experiment
38 10 Blackmore, Victoria
39 18 Blackmore, Victoria
[[10-1140-epjc-s10052-013-2582-8|Full Details]]
40 18 Blackmore, Victoria
41 12 Blackmore, Victoria
*Abstract:* 
42 12 Blackmore, Victoria
43 12 Blackmore, Victoria
    bq. A novel single-particle technique to measure emittance has been developed and used to characterise seventeen different muon beams for the Muon Ionisation Cooling Experiment (MICE). The muon beams, whose mean momenta vary from 171 to 281 MeV/c, have emittances of approximately 1.5--2.3 \pi mm-rad horizontally and 0.6--1.0 \pi mm-rad vertically, a horizontal dispersion of 90--190 mm and momentum spreads of about 25 MeV/c. There is reasonable agreement between the measured parameters of the beams and the results of simulations. The beams are found to meet the requirements of MICE. 
44 10 Blackmore, Victoria
45 13 Blackmore, Victoria
*Paper:*
46 13 Blackmore, Victoria
47 17 Blackmore, Victoria
Published in "European Journal of Physics C, Volume 73, Number 10 (2013)":http://rd.springer.com/article/10.1140%2Fepjc%2Fs10052-013-2582-8
48 33 Blackmore, Victoria
arXiv: "1306.1509":http://arxiv.org/abs/1306.1509
49 1 Long, Kenneth
DOI: "10.1140/epjc/s10052-013-2582-8":http://dx.doi.org/10.1140/epjc/s10052-013-2582-8
50 26 Blackmore, Victoria
"INSPIRE HEP":http://inspirehep.net/record/1258073?ln=en
51 13 Blackmore, Victoria
52 35 Rogers, Chris
"BibTeX":http://micewww.pp.rl.ac.uk/attachments/3272/references_v2.bib
53 13 Blackmore, Victoria
54 20 Blackmore, Victoria
*Figures:*
55 10 Blackmore, Victoria
56 24 Blackmore, Victoria
"Fig. 1":http://micewww.pp.rl.ac.uk/attachments/3259/figure1-eps-converted-to.pdf, "Fig. 2":http://micewww.pp.rl.ac.uk/attachments/3260/figure2-eps-converted-to.pdf, "Fig. 3":http://micewww.pp.rl.ac.uk/attachments/3261/figure3-eps-converted-to.pdf, "Fig. 4a":http://micewww.pp.rl.ac.uk/attachments/3262/figure4a-eps-converted-to.pdf, "Fig. 4b":http://micewww.pp.rl.ac.uk/attachments/3264/figure4b-eps-converted-to.pdf, "Fig. 5":http://micewww.pp.rl.ac.uk/attachments/3255/figure5-eps-converted-to.pdf, "Fig. 6":http://micewww.pp.rl.ac.uk/attachments/3256/figure6-eps-converted-to.pdf, "Fig 7a--f":http://micewww.pp.rl.ac.uk/attachments/3257/figure7a_f-eps-converted-to.pdf, "Fig. 8a--c":http://micewww.pp.rl.ac.uk/attachments/3258/figure8a_c-eps-converted-to.pdf, "Fig. 9a":http://micewww.pp.rl.ac.uk/attachments/3263/figure9a-eps-converted-to.pdf, "Fig. 9b":http://micewww.pp.rl.ac.uk/attachments/3277/figure9b-eps-converted-to.pdf, "Fig. 10":http://micewww.pp.rl.ac.uk/attachments/3266/figure10-eps-converted-to.pdf, "Fig. 11":http://micewww.pp.rl.ac.uk/attachments/3267/figure11-eps-converted-to.pdf, "Fig. 12":http://micewww.pp.rl.ac.uk/attachments/3268/figure12-eps-converted-to.pdf, "Fig. 13":http://micewww.pp.rl.ac.uk/attachments/3269/figure13-eps-converted-to.pdf, "Fig. 14":http://micewww.pp.rl.ac.uk/attachments/3270/figure14-eps-converted-to.pdf, "Fig. 15":http://micewww.pp.rl.ac.uk/attachments/3278/figure15-eps-converted-to.pdf
57 1 Long, Kenneth
58 20 Blackmore, Victoria
*Tables:*
59 20 Blackmore, Victoria
60 20 Blackmore, Victoria
"Table 1":http://micewww.pp.rl.ac.uk/attachments/3275/momentumTable.tex, "Table 2":http://micewww.pp.rl.ac.uk/attachments/3273/errorTable.tex, "Table 3":http://micewww.pp.rl.ac.uk/attachments/3274/summaryTable_v2.tex, "Table 4":http://micewww.pp.rl.ac.uk/attachments/3271/dispersionTable.tex
61 21 Blackmore, Victoria
62 21 Blackmore, Victoria
63 10 Blackmore, Victoria
64 10 Blackmore, Victoria
h2. The MICE Muon Beam on ISIS and the beam-line instrumentation of the Muon Ionization Cooling Experiment
65 1 Long, Kenneth
66 26 Blackmore, Victoria
[[10-1088-1748-0221-7-5-p05009|Full Details]]
67 1 Long, Kenneth
68 26 Blackmore, Victoria
*Abstract:*
69 1 Long, Kenneth
70 26 Blackmore, Victoria
bq. The international Muon Ionization Cooling Experiment (MICE), which is under construction at the Rutherford Appleton Laboratory (RAL), will demonstrate the principle of ionization cooling as a technique for the reduction of the phase-space volume occupied by a muon beam. Ionization cooling channels are required for the Neutrino Factory and the Muon Collider. MICE will evaluate in detail the performance of a single lattice cell of the Feasibility Study 2 cooling channel. The MICE Muon Beam has been constructed at the ISIS synchrotron at RAL, and in MICE Step I, it has been characterized using the MICE beam-instrumentation system. In this paper, the MICE Muon Beam and beam-line instrumentation are described. The muon rate is presented as a function of the beam loss generated by the MICE target dipping into the ISIS proton beam. For a 1 V signal from the ISIS beam-loss monitors downstream of our target we obtain a 30 KHz instantaneous muon rate, with a neglible pion contamination in the beam. 
71 1 Long, Kenneth
72 26 Blackmore, Victoria
73 26 Blackmore, Victoria
74 26 Blackmore, Victoria
*Paper:*
75 31 Blackmore, Victoria
76 32 Blackmore, Victoria
Published in "Journal of Instrumentation, Volume 7, Number 5 (2012)":http://iopscience.iop.org/1748-0221/7/05/P05009
77 33 Blackmore, Victoria
arXiv: "1203.4089":http://arxiv.org/abs/1203.4089
78 27 Blackmore, Victoria
DOI: "10.1088/1748-0221/7/05/P05009":http://dx.doi.org/10.1088/1748-0221/7/05/P05009
79 27 Blackmore, Victoria
"INSPIRE HEP":http://inspirehep.net/record/1094170?ln=en
80 27 Blackmore, Victoria
81 29 Blackmore, Victoria
"BibTeX":http://micewww.pp.rl.ac.uk/attachments/3326/10-1088-1748-0221-7-05-P05009.bib
82 29 Blackmore, Victoria
83 26 Blackmore, Victoria
*Figures:*
84 26 Blackmore, Victoria
85 26 Blackmore, Victoria
*Tables:*
86 6 Long, Kenneth
87 4 Long, Kenneth
88 4 Long, Kenneth
[[analysis:|Back]]